Sampling Process for Serialized SFC

Hello Experts, I had some issue with setting up sampling for serialized SFCs.  No matter how I set up for the sample plan I always get an error "No SFC group meets SFC Group Size value" when I was...

View Article


Image may be NSFW.
Clik here to view.

Build Error in SAP NWDS 7.5 with SAP ME 15.1 & Java 8

Hi All, Need one urgent help. I am currently trying to develop a custom POD is SAP ME SDK. The NWDI track has been set up with SAP ME 15.1 will all SCA files pointing to the most recent version. I am...

View Article


BAPI_PRODORDCONF_CREATE_TT

Hello, I am trying to use BAPI_PRODORDCONF_CREATE_TT at a program,  however the Bapi return an error RU-510 "A confirmation function can only be executed in dialog mode"How to solve error code  RU-510...

View Article

SAP ME "SFC" functionality inside SAP Only

Greetings Experts! I am extremely familiar with the SFC feature of SAP ME, namely, a unique identifier used to track lots of wip (serialized or non-serialized) in the ME environment.Last I checked the...

View Article

Equipment Master Tracking on non-serialized Materials; possible?

Hello Experts!I love what the equipment master can do to tie together my serial number data to WIP tracking. I would like to have this functionality on non-serialized lots that I am also building,  for...

View Article


Default value for SFC worklist

Hello experts,when trying to change the maximum number of rows in the list maintenance for the worklist SFC_ACTIVE_TOUCH I am getting the following information "Maximum row limit exceeded the default...

View Article

Re: Error in posting order confirmation from SAP ME

Hello Experts, When I try to post a confirmation for the operation from SAP ME, I am getting following error in MEINT:  Error evaluatin xpath...

View Article

Image may be NSFW.
Clik here to view.

Error while searching in Audit_Log_Error

Hello experts, I ran into an internal error after input search criteria and hit search button.  However, after I checked the error message in NW, there showed the following information: ASJ.ejb.005044...

View Article


Operation-ID digit limitation for Collaboration

Hi all We're using yield confirmation collaboration regulative. Sometimes it works, sometimes it doesn't. If it Fails, it doesn't create the XML-file. We get the error message...

View Article


How do we create RMA number without using NextNumber logic in SAP ME?

Hi, I have to create an RMA number in the SAP ME system with the same name of which i am getting it from ERP. So, Is there any standard API's are available in ME for this function instead of doing it...

View Article

Application_Setting table - SQLTRACE.tl_state

Hello, In our ME 5.2 system,I have a question about the Application_Setting table - SQLTRACE.tl_state setting, I couldn't find a place to set it in the manufacturing pages. Can you please advice where...

View Article

Image may be NSFW.
Clik here to view.

SFC closed when closing the Shop Order

Hello, I realized a problem when we try to close the Shop Order. We have the system rule "SFC Status on Shop Order Close" taking from the Global rule, which was 405. I understood it means, when we try...

View Article

Increasing number of SFC shown in worklist

Hi, In POD - Operation the active worklist has a maximum of 100 SFC's shown. Is it possible to change the number of SFC's shown? We have SAP ME version 6.0.4.44 Best regards,Johan

View Article


Data Collection stored in ODS

Hi, We have set the system rule "Store Data Collection Results in ODS" to TRUE. In what ODS table will the Data collection results then be stored? Best regards,Johan

View Article

How to send custom parametric data with XML to SAP ME 6.0

Hello, I'm trying to send custom parametric data with old XML messaging to SAP ME 6.0. Default parametric data I'm able to send but custom parametric  info is not saved to db (PARAMETRIC_CUSTOM...

View Article


Automatically display work instruction in operating POD

Hi experts, I've been trying to automatically display a work instruction in an operation POD.I changed the rule AUTO_DISPLAY_REQUIRED to YES for the activity WI500.In the POD I used WI_LIST_DISPLAY as...

View Article

packing sfc take long time

hi, packing takes a long time when the number of packed SFC is over 100 st. I attached a log file from one example when I tried to pack one sfc. the packing time can increase to 10-20 s for every SFC...

View Article


NC Data table details

Hello, Any idea what’s the difference between assembly_incident_num and batch_incident_num in the nc_data table (in WIP DB) and how it’s generated? -Adarsha.K.S

View Article

how to log one tool on more than one resource at a time

Hi experts i am looking for a way to log one tool on two resources at the same time.I tried to model this in the system by creating a tool group with tracking control lot and tool quantity 2creating a...

View Article

WPMF iFrame-Plugins ... Missing IFrameOnMessageListenerInterface